Título : | Repeatability of heart rate variability in congenital hypothyroidism as analysed by detrended fluctuation analysis |
Creador: | Echeverría JC |
Nivel de acceso: | Open access |
Palabras clave : | Hipotiroidismo Congénito - diagnóstico - niño Hipotiroidismo Congénito - fisiopatologia - niño Electrocardiografía - métodos - niño Electrocardiografía - normas Frecuencia Cardíaca - fisiologia - niño Reproducibilidad de Resultados Congenital Hypothyroidism - diagnosis - child Congenital Hypothyroidism - physiopathology - child Electrocardiography - methods - child Electrocardiography - standards - child Heart Rate - physiology -child Reproducibility of Results Dinámica de RR, exponente de escalamiento, correlación intraclase, capacidad de intercambio RR dynamics, scaling exponent, intraclass correlation, interchangeability |
Descripción : | The analysis of heart rate fluctuations, or heart rate variability (HRV), may be applied to explore children's neurodevelopment. However, previous studies have reported poor reliability (repeatability) of HRV measures in children at rest and during light exercise. Whether the reliability can be improved by controlling variables such as physical activity, breathing rate and tidal volume, or by selecting non-conventional techniques for analysing the data remains as an open question. We evaluated the short-term repeatability of RR-interval data from medicated children with congenital hypothyroidism (CH). The α1 exponents, obtained by detrended fluctuation analysis (DFA), from the data of 21 children collected at two different sessions were compared. Elapsed days between sessions were 59 33, and data were obtained during 10 min, trying to restrict the children's activity while being seated. We found statistical agreement between the means of α1 exponents for each session (p = 0.94) and no bias with a low-coefficient variation (9.1%); an intraclass correlation coefficient ri = 0.48 ([0.14 0.72], 95% confidence interval) was also estimated. These findings, which were compared with results obtained by conventional time and frequency techniques, indicate the existence of agreement between the α1 exponents obtained at each session, thereby providing support concerning the repeatability of HRV data as analysed by DFA in children with congenital hypothyroidism. Of particular interest was also the agreement found by using the central frequency of the high-frequency band and the parameter pNN20, both showing better or similar ri than α1 (0.77 [0.57 0.89] and 0.51 [0.17 0.74], respectively), yet considerably better repeatability than other conventional time and frequency parameters. © 2009 Institute of Physics and Engineering in Medicine. |
Colaborador(es) u otros Autores: | Solís LI Pérez JE Gaitán MJ Rivera IR Mandujano M Sánchez MC González-Camarena R. |
Fecha de publicación : | 2009 |
Tipo de publicación: | Artículo |
Formato: | |
Identificador del Recurso : | 10.1088/0967-3334/30/10/003 |
Fuente: | Physiological Measurement 30(10):1017 - 1025 |
URI : | http://repositorio.pediatria.gob.mx:8180/handle/20.500.12103/2767 |
Idioma: | eng |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.